Elementary overview
OSFOEC.016 explains how a short patterned section of optical fiber can become a sensor for strain and temperature. A fiber Bragg grating (FBG) contains periodic changes in the refractive index of the fiber core. Most wavelengths pass through; a narrow band reflects toward an optical interrogator. When the grating stretches or warms, its reflected wavelength shifts. Engineers measure that change to infer a physical condition, provided the sensor is properly calibrated.
The previous OSFOEC.015 Brillouin lesson examined distributed strain measurements along fiber. FBGs instead represent identifiable sensing regions, although many gratings with separate wavelengths can share one fiber. HBM FiberSensing documents their reflection principle, multiplexing and interrogation methods.
The Bragg wavelength and what changes it
The basic reflection condition is λB = 2neffΛ, where λB is the Bragg wavelength, neff is effective core refractive index and Λ is grating period. Mechanical strain changes spacing and refractive index; temperature also changes the index and causes expansion. Both effects can move a peak that an interrogator measures. The Smart Fibres technical overview discusses the physics and optical readout.
Near 1550 nm, literature commonly cites approximately 1.2 picometers per microstrain (pm/µε) and approximately 10 pm/°C for conventional silica FBGs. Those values are illustrative, not universal specifications: fiber composition, encapsulation, bonding, temperature range and calibration affect actual sensitivity. A technical peer-reviewed review reports comparable representative coefficients.
A worked strain and temperature example
Assume a fictional classroom sensor initially reflects at 1550.000 nm and later at 1550.240 nm. The measured change is 0.240 nm = 240 pm. If temperature truly remained constant and strain sensitivity were 1.2 pm/µε, the estimated strain change would be 240 ÷ 1.2 = 200 µε. Microstrain means millionths of relative change in length.
Now suppose an independent, properly compensated temperature measurement shows a rise of 10°C and the grating’s thermal coefficient is 10 pm/°C. Temperature would explain an estimated 100 pm; the residual 140 pm corresponds to approximately 117 µε. Neither answer should be presented as a measured bridge deformation: the coefficients and readings are hypothetical. HBM describes reference gratings and other temperature-compensation approaches.
Interrogators, multiplexing and measurement limits
An interrogator illuminates the fiber and tracks reflected spectral peaks. Several FBGs can occupy one fiber when their wavelength ranges remain distinguishable throughout expected motion and temperature changes. The number of usable sensors depends on source bandwidth, peak spacing, reflected power, losses and interrogator specifications. A drifting peak can be confused with a neighboring grating if the system is designed without enough guard range.
A grating glued to a structural member senses strain transferred through the adhesive, not automatically the full strain in the substrate. Installation quality, orientation, thermal gradients and sensor protection matter. For contrast, OSFOEC.014 covers Raman distributed temperature sensing; OSFOEC.013 discusses OTDR event interpretation. Neither instrument is a substitute for an FBG interrogator.
Read-only engineering exercise
Review an approved historical dataset containing wavelength, time and independent temperature readings. Identify each grating’s reference wavelength and calibration coefficients. Calculate wavelength shifts, apply the documented temperature model and chart the remaining inferred strain. Flag overlapping peaks, missing reflections and abrupt baseline jumps rather than silently interpolating. Use OSFOTC.005 to review optical-connector handling and measurement discipline.
Never stare into fiber ends or connect unidentified active optical ports; infrared sources may be invisible. Field installation on bridges or machinery requires authorized access and approved mechanical and electrical safety procedures. Learning conclusion: an FBG translates local strain and temperature into a wavelength shift, but reliable engineering measurements require calibrated sensitivities, peak tracking and compensation for coupled effects.